When the heating comes on for the first time in autumn, our phone fills up with radiators that are warm at the bottom and cold at the top. That is air trapped in the radiator, and you can almost always fix it yourself in five minutes. Here is how, and how to tell when it is something else.
What you need
A radiator key (a small brass key from any hardware shop, about £2). Many modern radiators take a flat screwdriver instead.
An old cloth or kitchen roll.
Five minutes, with the heating off.
Step by step
Turn the heating off and wait until the radiators are cool. Bleeding a hot radiator can spray hot water, and with the pump running you can pull more air in.
Find the bleed valve. It is the small square nut (or slotted screw) at one of the top corners of the radiator.
Hold the cloth under the valve, fit the key and turn it anticlockwise, about a quarter of a turn. You will hear a hiss as the air comes out.
Close it as soon as water appears. A steady dribble of water rather than spitting air means it is done. Turn the key clockwise until it is snug; do not over-tighten.
Do the rest of the house, starting with the radiator furthest from the boiler on the ground floor and working towards it, then upstairs.
Then check the boiler pressure
Bleeding lets a little water out of the system, so the pressure drops. Look at the gauge on the front of the boiler. With the system cold it should read about 1 to 1.5 bar; your boiler's manual gives the exact figure. If it has dropped below 1, top it up with the filling loop (usually one or two small taps on a braided hose under the boiler), opening them slowly and closing them as soon as the needle reaches the right level.
If you are not sure which taps are the filling loop, stop and ring us. Topping up the wrong way is one of the more common reasons we get called out.
When it is not air
Bleeding fixes a radiator that is cold at the top. Other patterns mean something else:
Cold at the bottom, warm at the top: sludge has settled in the radiator. It needs flushing, not bleeding.
Black water when you bleed it: the system is dirty inside, and the boiler and pump are working harder than they should.
One radiator cold all over: a stuck valve or a balancing problem.
You need to bleed the same radiator every week: air is getting in somewhere, or the system is losing water. Both need looking at before they damage the boiler.
The pressure keeps dropping after you top it up: there is a leak somewhere, often a small one under a floor.
Any of these is worth a call. Most are fixed in a single visit, and a radiator swap starts from £120 if one has simply reached the end of its life. We would always rather tell you how to fix something yourself than charge you for a key and five minutes.